Announcement

Collapse
No announcement yet.

User Profile

Collapse

Profile Sidebar

Collapse
Avatar
smilgy
New Member
Last Activity: 10-17-2024, 04:15 PM
Joined: 08-22-2022
Location: Dublin
  •  
  • Filter
  • Time
  • Show
  • Source
Clear All
new posts

  • All mosfets replaced. Majority of them were gone. Also some 22R1 SMD resistors beside the mosfets were dead as well, so I replaced them too.

    The unit now has more life than it did previously, which is good. It gives an AC output of 270V using a normal multi meter or 145V with a true rms meter for about 15 seconds or so, before the unit shuts down (you can hear a relay click).

    I'd did then check some downstream components, but didn't find anything obvious? I have a thermal camera, but nothing obvious comes up either.

    Any suggestions?
    See more | Go to post
    Last edited by smilgy; 09-26-2024, 03:06 AM. Reason: 9M64Tj

    Leave a comment:


  • Dometic SinePower DSP 1812T - No AC output

    Hey All,

    I have a Dometic DSP 1812T 1800W inverter with no 230V output. Previous owner said they plugged in a 2300W kettle and then it stopped working.

    I've taken it apart and found a manufacturing fault where the manufacturer forgot to put in some screws to attach the 12V DC side mosfets to their heatsinks. Naturally, these failed.. I can easily replace these, however want to know what else may have been damaged in the process?

    The inverter still worked in the sense that it would power up, display ON light, and some relays clicked.


    I...
    See more | Go to post