Monitor Is Fixed!!!
Thank-you all for your replies! My monitor works once again. I ordered a new replacement for the OZ9910GN as ivanlee05 had pointed out that the original chip's VREF measurement wasn't correct. This did the trick.
For those ever having to replace this chip for this model/version of monitor, know that after unsoldering it, that it is glued to the board. I used pliers to pull it off and in doing so I damaged a couple of traces which required jumping when installing the new chip. In retrospect I should've been more careful. Regardless, it now works...
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: Acer AL1916W Ab Monitor, DAC-19M008 - No Backlight, Recapped, Can see wFlashlight
No Shortcake1972, I'm still awaiting to see if anyone has any ideas myself. I imagine the source / cause of your problem may be different than mine as my board doesn't blow fuses.
Leave a comment:
-
Re: Acer AL1916W Ab Monitor, DAC-19M008 - No Backlight, Recapped, Can see wFlashlight
- The Backlight Inverter Transformer Secondaries measure 749 Ω and 752 Ω
- IC200 Voltage Results:
... IC200 ....... Power On .... Standby
Pin 8 (ENA) ..... 3.218v ....... 0.018v
Pin 12 (VREF) .. 2.345v ....... 0.001v
Pin 13 (VIN) .... 19.84v ....... 20.19v
Pin 8 does change state when the power button is pushed. When Powering On (Green Light) it goes from 0v to 3.2v for 3 seconds, back to...
Leave a comment:
-
Re: Acer AL1916W Ab Monitor, DAC-19M008 - No Backlight, Recapped, Can see wFlashlight
Another correction: I accidentally cut out the categories that make this make sense before the final posting:
- Logic Board Connector Pins 15 & 16 Voltage:
........... Active ... Standby
Pin 15 ... 3.27v .... 0.006v
Pin 16 .. 0.018v .... 3.25v
Leave a comment:
-
Re: Acer AL1916W Ab Monitor, DAC-19M008 - No Backlight, Recapped, Can see wFlashlight
Thanks for responding to my post. I have only now had time to sit down and check the monitor.
First off, I'd like to correct the error in my first post (for those possibly having this problem, and are reading this later) regarding the names of the MOSFETS, which should read (IC201, IC202).
Answers to previous questions:
- The Bulbs test OK.
I was able to check the bulbs of the monitor by plugging them into an inverter board from a separate...
Leave a comment:
-
Acer AL1916W Ab Monitor, DAC-19M008 - No Backlight, Recapped, Can see with Flashlight
Monitor: Acer AL1916W Ab
Inverter / Power Supply Board: DAC-19M008 BF Rev:01A
Manufactured: 8/2006
Status: Monitor works, but CCFL Bulbs don't come on at all. I can see the LCD display functioning properly with a flashlight held up to the screen.
Prior Symptoms: The monitor began to cease to come out of it's sleep mode correctly, in doing so the power button's amber LED light (sleep / screen save mode) would change to green when coming out of sleep mode, but the CCFL lamps wouldn't always come on unless I recycled the power by pressing the button off...Last edited by Anonymous333; 08-13-2010, 04:43 AM.
No activity results to display
Show More
Leave a comment: