It was just a dirty connector,it looked a bit dull compared to the other 2 ports so I gave the cable plug a squirt of contact cleaner worked it a bit now its working fine..
-
Version : 90.02.30.00.65 is what I have
Not done a VBIOS update before , will take a look / ....
Leave a comment:
-
I just checked and it seems to be on 30 Hz with no option to change it, I plugged it into the other display port and that does not show the scrambled image on startup and its on 60Hz but if i touch the cable it goes to black screen like the connector is bad .
Leave a comment:
-
The motherboard is a fairly new asus PRIME Z690-A (LGA1700) and both were working fine before I put this card in....
Leave a comment:
-
The video is from startup, it does not do it from sleep, Gpu msi gaming trio geforce rtx 2080 Ti...
Leave a comment:
-
Just gone into the bios and all looks like it should, interestingly it seem it only does it from power up not on a restart 🤔...
Leave a comment:
-
2080Ti startup issue ?
Hi I recently bought a 2nd hand Ge-force 2080Ti, it all works ok runs fine and no issues stress testing with furmark . However I get this screen when powering on (see video link) , is this cause for concern ? ....
-
-
Re: Hoverboard mosfet
Hi , what did you replace them with in the end ? , I an having the same issue .
Leave a comment:
-
Re: high esr on new rubycon caps
Thank you for the great advice ..
Leave a comment:
-
Re: high esr on new rubycon caps
So for power supply boards for example if i had no schematic or the capacitor which needed to be replaced, make could not be identified would it always be better to use low esr caps , ?
Leave a comment:
-
Re: high esr on new rubycon caps
Thanks for that info , learnt something new today , I will pay more attention when looking at esr charts in future .
So there must be different charts for low esr ?
Leave a comment:
-
Re: high esr on new rubycon caps
So as a general rule when replacing caps , i would need to see if the caps removed were low esr or not , ?
i just thought i needed to check capacitance value and voltage , .
Leave a comment:
-
Re: high esr on new rubycon caps
The caps i removed were JEC cd110 these are what i used to replace them :
[URL="https://uk.farnell.com/rubycon/50yxm47mefc6-3x11/capacitor-47uf-50v/dp/1281851"]https://uk.farnell.com/rubycon/50yxm47mefc6-3x11/capacitor-47uf-50v/dp/1281851[/URL]Re: high esr on new rubycon caps
The caps i removed were JEC cd110 these are what i used to replace them :
[URL="https://uk.farnell.com/rubycon/50yxm47mefc6-3x11/capacitor-47uf-50v/dp/1281851"]https://uk.farnell.com/rubycon/50
Leave a comment:
-
high esr on new rubycon caps
Hi , i just bought some 47uf 50v caps from farnell , the esr of the cap i took out was around 0.8 the new ones measure 1.8 which seems too high , are these a bad batch do you think ?
-
Re: CIT 700 w EN60950
not sure if this helps , its the voltages at the ic pins .
[ATTACH]165555[/ATTACH]...
Leave a comment:
-
CIT 700 w EN60950
Hi , i have been trying to fix the above atx psu ,I think it got quite hot , there was a LOT of dust inside the case and i the fan was not turning freely so may be was stopped .
There were some caps on the output which looked questionable so i replaced them all , i have +5 VSB and that is all .
When i connect it to a motherboard and hdd it works for a second then shuts down , if i leave the green wire and com shorted to power on , it works ok .
It uses a SG6105ADZ ic .
not sure where to go from here ..Last edited by moss99; 11-01-2017, 10:23 AM.
-
Re: powered sub wont come out of standby
Hi guys , im about ready to give up on this , i thought i had found something , i noticed when i moved this coil the led would flicker green/ red , i took the capacitor out next to it ,(circled in the drawing ) as couldnt get a reading from it from my esr meter .
Replaced it and after a few seconds the relay clicked and green led , tried it a couple times and seemed ok . but now back to red led again .
[ATTACH]153182[/ATTACH]...Last edited by moss99; 03-08-2017, 04:13 PM.
Leave a comment:
-
Re: powered sub wont come out of standby
Unfortunately apex have said the could not get the driver to this board , typical they have schematics for the good boards ,,
Leave a comment:
-
Re: powered sub wont come out of standby
[ATTACH]152938[/ATTACH]
These readings are with the relay removed , its an earlier photo .
On pin 1 (with the ground probe on center pin of J6) .3 v dc , on pin 2: -12 vdc .
with red probe on pin 1 and black probe on pin 2 i get 4 vdc.Re: powered sub wont come out of standby
[ATTACH]152938[/ATTACH]
These readings are with the relay removed , its an earlier photo .
On pin 1 (with the ground probe on center pin of J6) .3 v dc , on pin...Last edited by moss99; 03-05-2017, 04:28 AM.