Re: Hisense LHD32D33EU repair, vertical lines, T-CON, BOE HV320WX2-206 cell
I can easily fix this in just 30 minutes .That problem is related to missing Von or Voff on the COF ,the Cofs comes in about three different types .You will have yo bypass that missing voltage using a very small wire for my case I get those wires from 12v Relays .For more info about this am always available at no charge.Even on other models.
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: Panasonic TC-p58s2 no power
Finally I got the problem IC8000 is shorting due to the thermal pad contact with the heat sink ; which became loose due to time and the heat beneath so the only solution is to change the board A (mother board) but you have to take extra caution on that heat sink to see that it is firmly in place.
Leave a comment:
-
Re: Panasonic TC-p58s2 no power
I have got the same Tv TX-P50VT20B with exactly the same problem ,let me use this information and see whether I can overcome this problem.
Leave a comment:
-
Re: VIZIO M320SR inverted logo?
You have to enter the service mode and change the model version this is due to the corrupt eeprom data
Leave a comment:
No activity results to display
Show More
Leave a comment: