Announcement

Collapse
No announcement yet.

User Profile

Collapse

Profile Sidebar

Collapse
Avatar
ponyboy689
New Member
Last Activity: 04-03-2013, 09:59 AM
Joined: 02-26-2013
Location: N.F. Ontario
  •  
  • Filter
  • Time
  • Show
  • Source
Clear All
new posts

  • Re: Lg plasma 42PQ60 relay clicking

    I did load m5v with a 100ohm resistor and it was okay

    Here's an update, I think my M5v is okay. I think its the control PCB.
    When i jump 5V from smps to pin 1 of ic211, on the control PCB, i get the dreaded relay clicks. the manual says the led should blink, i don't get the blinking i only get the relay clicks, Also if the ribbon cable is plugged in from the y-sus to the control pcb i get clicks. Could it be the control board.
    See more | Go to post

    Leave a comment:


  • Lg plasma 42PQ60 relay clicking

    I've done most of the test that's outlined in the training manual from lg. and i came to the conclusion that something is wrong with my mV5, it seems the relay clicks constantly when this used in the circuit. When there's no load it works, Can this be a main board problem ?

    There's one test where i'm trying to test the control board, put a jumper from pin 10 of p811 (m5v) to pin 10 P201 (5v), i can't get this to work because my relay keeps clicking. I'm losing m5v when there is a load.
    See more | Go to post
No activity results to display
Show More
Working...
X