Login or Sign Up
Logging in...
Remember me
Log in
Forgot password or user name?
or
Sign Up
Log in with
Sign-in with Twitter
Sign-in with Google
Switch to our
Advanced Forum Search
Advanced Search Options:
Multiple Words
What it does:
searches for web pages that include either word
What to type:
macbook A2141 boardview OR schematic
What you'll get:
results with the words "macbook AND A2141" and either "boardview" or "schematic"
examples:
Macbook A1502
or
GTX 1080 Boardview
or
Playstation 5 Firmware
Search in titles only
Search in posts by neuron only
Search
Advanced Search
Forums
TUTORIALS
DONATE CRYPTO
Advanced Search
Forum Community
Today's Posts
neuron
New Members (required)
Introduce yourself here
. Read the
Forum rules here
.
Announcement
Collapse
No announcement yet.
User Profile
Collapse
Profile Sidebar
Collapse
neuron
Senior Member
Last Activity: 12-29-2020, 05:25 PM
Joined: 02-19-2013
Location: Imagina
Subscriptions
1
Subscribers
0
Activities
About
Media
Subscribed
Filter
Time
All Time
Today
Last Week
Last Month
Show
All
Discussions only
Photos only
Videos only
Links only
Polls only
Events only
Source
All
neuron only
Visitor Messages Only
Advanced
Filtered by:
Clear All
new posts
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-29-2020, 05:25 PM
Re: Koban - Current Clamp Meter - DMM
Only C31 Burn
I power up and tested all function
V, Ohm, Hz, Diode, ÂșC, ... don't see any errors
Zero, Hold, Select.
Ruy...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-27-2020, 05:45 PM
Re: Koban - Current Clamp Meter - DMM
stj - the only info is MASTECH MS8250B (sigrok.org)
It's in japan. and no info about the cap ......
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-25-2020, 07:09 PM
Re: Koban - Current Clamp Meter - DMM
UT61E is ES51922 !!!
IC11 I can't find ...
DMM use Semico CS7721CN - Semico CS7721CN: UT60C, UT60A
Diode mode?
2TY - I don't need remove from the board.
All my DMM can test Transistors in Boards.
And where I can find that schematics?
In your attach XC61xx.PNG the cap between Vin and ground ... value?
Ruy...
See more
|
Go to post
Last edited by
neuron
;
12-25-2020, 07:16 PM
.
Leave a comment:
Post Comment
Cancel
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-24-2020, 04:53 PM
Re: Koban - Current Clamp Meter - DMM
Thank you stj, megaraider
2TY 2 - Emitter -> down -> 2 Layer, through hole.
2 - Emitter -> up , Left -> C letter ->
U3 pin 2 VSS -> C31
U3 - pin 1 (down) -> 2 Layer, through hole -> the other C31 pin
Testing U3 (Diode Mode) I get +- 0,56V
Other procedure to test this IC?
Regard,
Ruy...
See more
|
Go to post
Last edited by
neuron
;
12-24-2020, 05:01 PM
.
Leave a comment:
Post Comment
Cancel
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-22-2020, 10:34 AM
Re: Koban - Current Clamp Meter - DMM
Boa tarde megaraider,
And the procedure to test ?
The last letter ... is necessary?
C31 no info?
I can follow the tracks in the board and
tested 2TY and all resistors around the C31.
C31 in the board ...?
Thank you
Ruy...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-19-2020, 05:48 PM
Re: Koban - Current Clamp Meter - DMM
Thank you,
CHX ... one more letter or number in Koban_1.JPG
I can't find PDF with that reference.
Thank
Ruy...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
started a topic
Koban - Current Clamp Meter - DMM
in
Equipment Usage, Soldering, Techniques, and Reviews
12-18-2020, 08:03 AM
Koban - Current Clamp Meter - DMM
The factory / reseller ... don't know anything about the device (Schematic, Service manual, etc)
and I need to repair this DMM - Clamp Meter.
2TY - Transistor - Q5 (Diode mode ok)
CHX ??? 5 Pins - U3
C31 ??? Burn,
Tested - V, Ohm, Diode, ÂșC ... don't see any errors
Thanks in advance for all info
Ruy...
See more
|
Go to post
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
11-29-2019, 06:09 AM
Re: Grundig CUC120 CRT TV
Thank you.
Please your comments:
Brightness and Colour Pot.: OK
But Contrast Pot.: I can' rise
no FOCUS and
washed out -> I only see a Blank RASTER.
Best Regards,
Ruy
See more
|
Go to post
Last edited by
neuron
;
11-29-2019, 06:20 AM
.
Leave a comment:
Post Comment
Cancel
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
09-25-2019, 10:22 AM
Re: Grundig CUC120 CRT TV
Thank you for your comments, info.
Works
Brightness and Colour Pot.: Min -> Max OK
Contrast Pot.: Min -> middle ok
But I can' rise
If I push this Pot. the image:
large ...
no FOCUS and
washed out -> I only see a Blank RASTER.
Note: This Model and CUC220, CUC720 almost identical
Best Regards,
Ruy
See more
|
Go to post
Last edited by
neuron
;
09-25-2019, 10:26 AM
.
Leave a comment:
Post Comment
Cancel
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
08-17-2019, 06:00 PM
Re: Grundig CUC120 CRT TV
Thank you for your comments, info.
In Sch. is 24V ... ? But in C2762 is 26V?
OK
And the rest ... points ...
In X = 108 V
1) T2566, T2567, T2568 -> T2566, T2576, T2586
Ok I will check.
2) My Mult. have Max, Min, and Crest.
The Var. is 1, 2V in +C, +A ... mV in +M, +B, +G
3) Tested R392, R393, R394, R396.
4) Yes several, but no Isolation Transformer in this House/Lab
Best Regards,
R...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
08-16-2019, 08:10 AM
Re: Grundig CUC120 CRT TV
NOTE: I would like to edit the msg but it's not possible.
In Pag. 1, I try test point R, A, D ... with multimeter
but as you can see in pic 35 and 36, large spikes.
So the RMS is different from the values.
What is the Procedure?
Thank you,
Ruy
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
08-13-2019, 03:18 AM
Re: Grundig CUC120 CRT TV
Thank you for your comments, info.
In Pag. 6 ?
T256X, T257X, T258X - Amplif.
+C +200V,
T2597, C259X, R259X, D2599? or
Contrast - T2533, SSB and SB and all this part ... what is function, purpose?
In manual I can't see the procedure to setup this Pots.
Best Regards,
Ruy...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
08-12-2019, 05:42 AM
Re: Grundig CUC120 CRT TV
This is a Super Color A 7100
The other sub-models in pag.1 - pdf
right bottom
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
started a topic
Grundig CUC120 CRT TV
in
Troubleshooting TVs and Video Sources
08-11-2019, 05:38 PM
Grundig CUC120 CRT TV
Hi,
I have CUC120 CRT TV to repair:
elektrotanya.com/grundig_cuc120.pdf/download.html
The screen is black ... and we notice from time to time (when
the image is very brig.) some small part of image.
Very few dots.
I tested the G1 2X V , G2 5XX V , Heather, Power Suply ...
Thank you,
Ruy
See more
|
Go to post
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-11-2019, 05:04 PM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
It's working and calib.
Thank you for all info and support,
Ruy
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-17-2018, 06:33 AM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
Thank you
In local stores:
MOTIP
[url]https://www.motip.com/products/motip/industry/professional-technical-solutions/contact-cleaner/[/url]
[url]https://www.wd40specialist.com/products/contact-cleaner[/url]
[url]http://cyclo.com/cyclo_product/break-thru-electronics-cleaner/[/url] 87
[url]http://cyclo.com/cyclo_product/break-thru-energized-circuit-contact-cleaner/[/url] 85
Any use in your equip.?
Re: Oscilloscope UNAOHM
...
See more
|
Go to post
Last edited by
neuron
;
08-17-2018, 06:34 AM
.
Leave a comment:
Post Comment
Cancel
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-15-2018, 05:33 PM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
What you use? brand model
And eccerr0r in 2465 ... Tek 2440?...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-15-2018, 09:32 AM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
bad/dirty contacts,
Inside ... pot, potentiometer ... switch contacts,
carbon pelic.
Thank you eccerr0r...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-14-2018, 04:26 PM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
Clean the front panel - Knobs, Handles, Pulls and Switches what you suggest?
And you have videos ?
Or text explan the process ?...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
neuron
replied to
Oscilloscope UNAOHM G4020 = BECKMAN 9020
in
Equipment Usage, Soldering, Techniques, and Reviews
08-13-2018, 06:22 AM
Re: Oscilloscope UNAOHM G4020 = BECKMAN 9020
Amazing DataBase !!!
And Tek is Up and Running?
Thank you
With Acetone, Benzine, Konkat ...?...
See more
|
Go to post
Leave a comment:
Post Comment
Cancel
No activity results to display
Show More
Working...
Yes
No
OK
OK
Cancel
X
Leave a comment: