I got a scangrip I-View 03.5626 "Superior COB LED headlamp with sensor"
These supposedly are high quality.
The usual discounted price is 60Eur.
While the headlamp seems to work OK, it lasts 1.5HRS as per manufacturer spec. The headlamp charges to 1345mA to a integrated battery that suppose to be 1600mA. The manufacturer explained that this is software cut-off and true capacity is higher because battery does not discharge fully.
Well I did not disasemble the headlamp yet to verify. But the SCANGRIP POWERBANK 03.5782 - quiescent current draw...
Thank you to the guys at HEGE supporting Badcaps [ HEGE ] [ HEGE DEX Chart ]
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
SCANGRIP POWERBANK 03.5782 - quiescent current draw 39mA
-
Re: ATX PSU SL-500 Short circuit can't find where? Transformer?
I think you did not read whole thread, all components tested OK that is why I removed the bulb. If I had a variac I would use lower AC voltage to see what heats up. But sometimes it is more easy to let parts explode then to find the problem....
-
Re: ATX PSU SL-500 Short circuit can't find where? Transformer?
The transistors on primary side heatsink were desoldered and tested OK.
The Viper22A is unknown condition.
Diode near viper is OK.
All other coponents on primary side are OK with testing using multimeter without desoldering. Any ideas?
Leave a comment:
-
Re: ATX PSU SL-500 Short circuit can't find where? Transformer?
I changed the Viper22A and diode from another PSU. The Transformer was also changed (to blue colored one the resistances are not as close to the posted above) as the first one had 1ohm on primary after magic smoke came out from other parts.
But after connecting trough the light bulb the thermal camera shows overheating capacitor. Connecting to mains direct makes the cap explode with loud bang ...
Leave a comment:
-
Re: ATX PSU SL-500 Short circuit can't find where? Transformer?
Well I found similar transformer in another PSU, and repalced it.
My meter measures only uH,mH value, and resistance.
The readings are in post above.
The PSU did not start, in fact the short circuit was still there.
I could not find. The VIPER22A was overheating 100deg C....Last edited by smile; 08-06-2022, 03:43 PM.
Leave a comment:
-
Re: HP Z820 v2-ivy-bridge-upgrade
How to replace the data? HxD ?
ME: 0x005000 to 0x50FFFF
Boot block region: 0xFF0000 to 0xFFFFFF
How solve the "ME is in manufacturing mode" msg during booting. ???
Leave a comment:
-
Re: HP Z820 v2-ivy-bridge-upgrade
It seems I found SOP16 DIP8 test clip here
[url]https://www.aliexpress.com/item/32681208043.html?pdp_npi=2%40dis%21USD%21US%20%247.21%21US%20%246.13%21%21%21%21%21%402101d1b916590288369635927ecf97%2160349232142%21im[/url]
Meanwhile hope you guys can help me with information about the bios flashing.Re: HP Z820 v2-ivy-bridge-upgrade<br...142%21im[/url]
Leave a comment:
-
HP Z820 v2-ivy-bridge-upgrade
Hello,
Hello, got my Z820 workstation today. The serial number is
SP P/N 619562-001
CT PBLP0CM42L3K9
AS P/N 618266-001 2012
PCB Rev: 1.00
Bios is latest version J63 V03.96 12/28/2011
I have a EZP2019 High Speed USB SPI Programmer and have done few laptop bios upgrades / recoveries. Any help in upgrading the BIOS?
I read the guide at [url]https://github.com/SuperThunder/HP_Z420_Z620_Z820_BootBlock_Upgrade[/url]
1. So far it's unclear how to connect sop16 clip to the EZP2019. Is there adapter...
-
Re: ATX PSU SL-500 Short circuit can't find where? Transformer?
Well replaced the transformer for +5VSB that is for sure not 0.08ohm resistance, but the result is the same short circuit bulb shines bright. Still waiting for PWM IC.
"Do you have a "component tester" " - Have ESR meter, miliohm meter 2 wire, inductance meter, PEAK Atlas Atlas DCA Pro....
Leave a comment:
-
ATX PSU SL-500 Short circuit can't find where? Transformer?
Hello,
I got ATX PSU SL-500 PSU. Images Attached.
It has blown VIPER22A, that I replaced.
Connected trough light bulb the bulb glows very bright indicating a short.
I tested every component on hot side of PCB and can't find the short circuit.
However the problem goes away removing +5VSB transformer.
The winding in questions of +5VSB transormer shows 0.08Ohms, is this normal?...
-
Identify component Fractal Design fd-psu-in2b-750w
Hello, I have a Fractal Design fd-psu-in2b-750w PSU.
There is burned resistor. Unknown value.
Can you identify it?
CHIP IS TNY280...
-
Re: problem with Delta GPS750AB A PSU. No +5v VSB
Enamel coating dried but chirping is not gone.
I connected PSU to test board, about 250W load. It works runs benchmarks no problems.
However the chirping sound gets faster and faster with load.
Voltages are OK.
Very strange i double checked caps and my esr meters (2 of them) say all caps good including 2 big ones.
two big ones are 330uF and I measure 300uF, esr is within spec not more then 0.1Ohms
I connected anothe 220uF cap and it seems the cycle increased (without scope that is...Last edited by smile; 05-03-2022, 02:42 PM.
Leave a comment:
-
Re: problem with Delta GPS750AB A PSU. No +5v VSB
The videos are nice I'm a long time subscriber.
I have removed relay and one suspect choke, still the sound remains when PSU is started even without relay. I mean it does not start but sound still can be heared.
I applied enamel coating on all chokes, maybe that will fix it.
All line are working +12 +5 -12 +3.3 +5VSBLast edited by smile; 05-03-2022, 08:24 AM.
Leave a comment:
-
Re: problem with Delta GPS750AB A PSU. No +5v VSB
OK,
1. I replaced TNY chip with another one.
2. Replaced TVS diode
3. added a 2Ohm resistor (two 1Ohm resistors in series). Tried 1K but it burned.
Now the PSU does not burn the resistor and starts fine. I tested it with 50W light bulb. So the datasheet is wrong about resistor value !!!!!!
Another problem:
There is chirping sound from PSU once every second when I start it with NO LOAD.
Unstarted it is silent and stable 5VSB output.
If I connect 50W...Last edited by smile; 05-02-2022, 12:27 PM.
Leave a comment:
No activity results to display
Show More
Leave a comment: