Haha, you are absolutely right! It’s the perfect example of why the Right to Repair is so vital. It’s incredibly frustrating to have a perfectly fine piece of hardware—with a CPU that’s clearly alive and kicking—turned into a doorstop just because the manufacturer holds the OS binaries hostage.
I’ve already done the heavy lifting: restored U-Boot via UART, wiped the corrupted NAND, and I’m literally sitting at the RCF-M18# prompt. The mixer is ready to be "reborn", but I'm missing the 50MB of data that RCF refuses to share even with independent labs.
...
User Profile
Collapse
-
[REQ] RCF M18 Digital Mixer - NAND Recovery files (uImage / ubi.img) or Dump
Hi everyone,
I'm working on a bricked RCF M18 digital mixer. The unit was completely dead, but I managed to resurrect the hardware doing a low-level recovery via the internal UART header and the Debug Jumper method (as per RCF Service Note 1903B).
I successfully booted from the SD card, wiped the NAND, and flashed U-Boot. The CPU is alive and I now have a working serial console at the RCF-M18# prompt.
The Problem:
The recovery script halted because the official firmware update provided by RCF on their website (.mpk format, ~1.5MB) is just an application...