Re: Another Westinghouse LCM-22w3
The solder adds (a little) to the current carrying capacity of the circuit trace like using a thicker copper but cheaper. As long as you didn't short any adjacent traces you'll be fine....
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: Mitsubishi Magna TR/TS / Verada KR/KS Engine & Transmission Controllers
I don't have a Sigma or the factory service manual for it but I suspect the TCU is in the same location as the Diamante/3000GT, on the floor of the center console below and in front of the ECU.
Make sure to replace the caps in both the TCU and ECU. If they are not bad yet after 20 years they will be soon....Last edited by steve; 03-14-2017, 07:59 AM.
Leave a comment:
-
Re: Samsung SyncMaster 226BW
I finally got around to ordering parts and got them today. The monitor is now working fine.
C107 47uF 50v Panasonic FC 105°C 6.3mm D x 11.2mm H P10321-ND
C111, C112, C114, C316, C317 820uF 25v Panasonic FM 105°C 10mm D x 25mm H P12391-ND
C113 330uF 25v Panasonic FM 105°C 10mm D x 12.5mm H P12386-ND
C118 2.2uF 50v Nichicon VZ 105°C 5mm D x 11mm H 493-1334-ND
C318 22uF 50v Panasonic FM 105°C 5mm D x 11mm H P12927-ND
I have extras for sale.
Leave a comment:
-
Re: Another Westinghouse LCM-22w3
I have two of these. Was it obvious as to how to open the case up to get at the board?
Leave a comment:
-
Re: Nichicon Loses Some Brownie Points
I searched high and low for the Rubycon MBZ parts when they first came out to replace the caps in all my Abit BX (BH6 and BX133) motherboards and you know how successful that turned out to be. At the time the Nichicon HN(M) looked to be a good second choice. That wasn't the case. I've now replaced the input and output caps on these machines several times due the the caps venting.
The HN(M) can't take the stress from of the old Celeron Coppermine CPU's.
Time to get some good caps.
Steve
Leave a comment: