Re: Acer P193w - blink screen
I have subst with DAEWOO units.
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: Acer P193w - blink screen
Service manual does not see this.
I have 6,89v at primary t501 and 6,89v at primary t502, but only for 2 secs at power on.
Whitout power it has 485 kohm and 482 kohm between the two out of t501 and t502
Leave a comment:
-
Re: Acer P193w - blink screen
I have 14,85v at d803; 5,08v at d805;
I have 14,85v at u502; 6,89v at u501 but in this case variable to 0v-6,89v continuosly.
I have changed 5 caps; 2 of 1000uF, 2 of 470uF and 1 680uF.
Leave a comment:
-
Re: Acer P193w - blink screen
I have the same problem, but if i connect all 4lamps it blinks if i connect only 3 lamps it still image for 3 secs. then off.
Leave a comment: