Re: not understanding the measurings I made on the K55VM board
Thanks for the reply, I suspect it could be something like that, I tried connecting a AA battery and the circuit draws 0,8A, couldn't find anything warming, there are so many caps connected in parallel it's hard to find the culprit, it could be a protection diode maybe... Must try with a power supply when I return to work bench, I was looking at the board at home with limited resources.
Anyway what I find strange is that the board was working fine from batteries, so the problem must be very close to the adapter...
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
not understanding the measurings I made on the K55VM board
Maybe someone can help as I'm not understanding the measurings I made on the K55VM board as follows:
the problem was that this Asus laptop was working on batteries and not charging. I took the board out and when measuring it seamed to exist a short to gnd in all regulator mosfets (drain to gnd and source to gnd) this can't be right as the computer was working...
I found that the A5 mos at supply input was in short circuit, I removed it from the board but I didn't put another one yet as I'm puzzled with this short circuit measure still found on the board.
Any ideas? What may...