Re: Xerox M20i power supply repair - KA7553
Changed PVD3 diode (which is 1A SUPER FAST RECOVERY RECTIFIER SF10-02) and SPMS seems to be OK, problem solved, tomorrow morning I will try in printer and will see.
Thanks for help
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Last edited by habaso; 02-03-2022, 12:47 PM.
-
Re: Xerox M20i power supply repair - KA7553
I had tried to help with powering KA7553 externally by voltage injection. With such VCC supported with voltage injection it stays OK, so there is no problem in following circuits, only somewhere in VCC part of KA7553 surroundings.
With VCC voltage injection
Red 5V output
Blue VCC of KA7553
Without VCC voltage injection
Red 5V output
Blue VCC of KA7553
...
Leave a comment:
-
Re: Xerox M20i power supply repair - KA7553
My real circuit is little bit different, there is PVD3 and powering part of circuit, but VCC is directly by zener diode (like PZD3, but without PC32, only with PC12) connected to ground.
I had take out this VCC grounding zener and VCC still cycling between 9V and 16V.
Leave a comment:
-
Re: Xerox M20i power supply repair - KA7553
Both PVD3 and zener diode are open one way and closed other and show around 600mV voltage drop open way using multimeter diode test.
Would you like to see some oscilloscope measured signal i.e. from not vcc side of PVD3 diode?
Leave a comment:
-
Re: Xerox M20i power supply repair - KA7553
47uF 35V capacitor was replaced.
Both diodes seems to be OK using multimeter diod testing, but I do not know if zener diod working on correct parameters now as new one.
Leave a comment:
-
Re: Xerox M20i power supply repair - KA7553
Capacitors were replaced, but I could not find wrong between them.
KA7553 and optocoupler were replace in attempt to solve problem, but SPMS stays in same state, so I think they were good before.
VCC you can see on picture, 1 oscilloscope "click" is 5V, co VCC cycling up and down between 9V and 16V. I do not know if this VCC cycling is OK a what caused it.
Do you think it can bee caused by zener diode?Last edited by habaso; 02-02-2022, 10:16 PM.
Leave a comment:
-
Re: Xerox M20i power supply repair - KA7553
Without load.
BUT I have to write as well, SPMS is more complex than schematics, from 5V it has to produce some other voltages, even high for blade etc. When trying optocoupler I have tested 5V "voltage injection" and there was not problem with that, so I hope there is no shortage inside this other following parts of SPMS.
KA7553 was replaced, all capacitors were replaced as well with optocoupler.
Red 5V voltage line
Blue VCC of KA7553
Red 5V voltage line
...
Leave a comment:
-
Xerox M20i power supply repair - KA7553
I am trying to repair SPMS based on KA7553.
Schematics (not exactly the same, but almost same usage of KA7553)
SPMS cycling, it produce correct output voltage, than goes down.
Red - output voltage
Blue - gate of MOSFET
Please advice what to check else? Datasheet of KA7553 is really not so informing. I have checked both FB and CS of KA7553 and as I understand datasheet, both of these inputs are lower than threshold voltage of overload or overcurrent shutdown.
...
-
Re: New Members - please post your introductions here
Hi everyone
I am here looking for you experienced advice and discussions
Leave a comment:
No activity results to display
Show More
Leave a comment: