  • Re: Philips 60PFL8708S/12 - QFU1.2E LA - Error code 53

    The TV has worked fine in my house during a rew days. Then it traveled a hundred+ km to my daughter's house. And there it started well but is beginning to stop working after some minutes. I will recover it later and I will tell you if the PCB is bent.
    What I plan to do is to reflow it again in the oven, then reinstall the foam pad below the SSD board to keep it as flat and stable as possible. And finally install some kind of clips on the heatsink to apply it as tight as possible to the SSB IC.
    See more | Go to post

    Leave a comment:


  • Re: Philips 60PFL8708S/12 - QFU1.2E LA - Error code 53

    Some months ago I posted concerning the revival of my 47pfl7108h_12 TV set by blowing hot air to the SSB CPU.
    Unfortunately after some time it began stopping and restarting without reason, till it completely stopped with the well known LED blinking.

    I did not read the last post about a day cooking (sorry Davi.p), so I applied another method (inspired from another blog post) which I will call the "Kitchen oven reflow".
    You will see on attachment the SSB PCB in the oven, set on bolts and...
    See more | Go to post

    Leave a comment:


  • Re: Philips 60PFL8708S/12 - QFU1.2E LA - Error code 53

    Hi everybody. I have very much appreciated this thread related to Philips smart TV revival.
    I have a 47PFL7108 model which was randomly stopping, sometimes restarting by itself or otherwise blinking the LED two times. When in SDM mode the error code was 53, just like on your sets.
    After several trials I have carefully applied the method described by NAVI.P and ALPENGEIST (thanks to them). I used a hot air gun delivering approximately 250°C, during less than 1 minute on the Fusion 120 chip, after protection of...