Re: Philips 49PUT5801/98 PANEL PROBLEMS ON BOTH HALVES
Already did that and see the attached pictures. It breaks my heart!!! Now it appears that after measurement, both sides of the scalar panel PCB are shorted to ground at the set of 4 MLCC caps....
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
-
Philips 49PUT5801/98 PANEL PROBLEMS ON BOTH HALVES
So this Philips TV has backlight but no image. VGH voltage was 0, so decided to buy a replacement TCON board. Fitted new board to no avail. Now panel PCB control boards have multiple shorted MLCC caps on both sides. TCON ICs hot to the touch suggesting that panel drawing more current than usual (internal short?)
Measured voltages on new TCON as follows :
VGH (29.67V)
VGL1 (-4.97V)
VGL2 (-14.89V)
VCC (3.282V)
VCORE (1.202V)
HVDD (7.95V)
VDD (15.97V)
VIN (11.98V)
VCOM1 (4.25V)
VCOM2 (4.63V)
Removed caps that were...Last edited by limtk55; 11-21-2020, 06:30 AM.
-
Re: Sony XBR49X900E no picture
This is not a TCON, mainboard or power supply issue.
It is an inverter and backlight issue. Try troubleshooting along that line and use back your original boards.