Re: A2289 Board 820-01987-A Dead?
Hi, same issue with ultrasonic cleaning
Thank you to the guys at HEGE supporting Badcaps [ HEGE ] [ HEGE DEX Chart ]
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: A2289 Board 820-01987-A Dead?
I have an ultrasonic cleaner, I will try. What temperature and time settings do you recommend ?
Leave a comment:
-
Re: A2289 Board 820-01987-A Dead?
Yes joutrade 5,12V present on L8504 (pin 1 and pin 2)Last edited by dbteckos; 03-09-2021, 10:14 AM.
Leave a comment:
-
Re: A2289 Board 820-01987-A Dead?
Hi momoomar, unfortunately not. I left it out for now waiting a real boardview.. But maybe you can help me.
Could you please tell me what voltage you get on the testpoint (beside J8401) with the red arrow on the photo and also diode value when board is disconnected from power ?
Thanks
PS: If U7420 is blown you should try to replace it...
Leave a comment:
-
Trace identification on 820-001987-06 Logic Board (MBP 13" A2289 2020)
Hello all,
I have a 820-01987-06 Logic board to repair, does anyone know what the testpoint is connected to at the red arrow on the picture ? It is completely destroyed.
Thank you for your kind responses...Last edited by dbteckos; 12-29-2020, 10:29 AM.
-
Re: A2289 Board 820-01987-A Dead?
Hi,
I have same Logic Board to repair (820-01987-06) and have 20V with 48mA which stays stable to this value. I can feel CPU warming but I have no image on the LCD and not on external display anymore. The LCD is ok, I have tested it with a working board.
I have noticied if the TrackPad is not connected, there is a current consumption (max 0,62mA) and drops to 0 after few seconds. That's why I'm asking me if this board needs the to communicate with TrackPad to be able to boot.
I retrieve similar resistance...
Leave a comment:
No activity results to display
Show More
Leave a comment: