Re: [FAQ] Atten 858d problem S-E (or 5-E) or stuck in 498'C.
Yes correct, I hold 2 buttons and I have like 3 seconds to set a default temperature...
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: [FAQ] Atten 858d problem S-E (or 5-E) or stuck in 498'C.
Only setting I found is pressing the 2 buttons at the same time and I can set the default power-on temp. And it gets remembered by the EEPROM.
As for the replacement firmware ... I would consider it but would rather start with a fully functional unit before...
Leave a comment:
-
Re: [FAQ] Atten 858d problem S-E (or 5-E) or stuck in 498'C.
I tried every input pin with a jumper (both high and low) without any success of finding "the hidden input"
Seems like the device was not programmed with a standby mode but the manual says clearly that it has one ...
I bought the first unit, returned it and now this one has the same problem. I wondered if I could repair it easily but seems like I will also return this 2nd piece of Chinese cr*p !!...
Leave a comment:
-
Re: [FAQ] Atten 858d problem S-E (or 5-E) or stuck in 498'C.
Hi to all,
I have a Sigma R700 (858D clone) and would like to repair it.
PCB is marked SBK858D 2017.01.03
The heater is always ON no matter it is on the holder or not. I troubleshooted the whole circuit and the reed switch is good.
On microcontroller input P0.1, I get 5V when off the holder and 0V when on the holder.
Am I missing something here ? Any other conditions in the firmware would keep the heater ON all the time ?