  • Re: Muskoka 35" curved fireplace power supply.

    I have found this because I have the same problem.
    The first thing I found strange is that the ON/OFF switch is in the neutral line.
    This then goes to Relay 1 on one of the top spade connecters.
    On the other side of the board this is the point red inked as the normally open contact, not the red inked common contact.
    This tallies with BUD M's diagram dated 04/17/2015 (American date format. In Uk that is 17/04/2015).
    There are in fact two motors on this, one for the flame effect and the second is built...
    See more | Go to post
    Last edited by tc4332; 11-05-2017, 05:59 AM. Reason: Added reference to BUD M's diagram

    Leave a comment:


  • Re: New Members - please post your introductions here

    Hi All,
    New kid on the block.
    This is the first month of my 79th year. Ex IBM Customer Engineer and GEC Motorway Engineer.
    Obviously a long retitred (sort of) knowledge soaker in the UK.
    Now doing a fair bit of tour coach driving over Europe, when the bug bites one cannot let go!!
    See more | Go to post

    Leave a comment: