Re: Fun with a couple of LG sets, 452PJ350 and 42PJ550 Y-SUS
Hello i got one set model is 42pt350r when checked yboard mosfets and z board mosfets were blowed up..replaced with new one..set was running perfect after one hour it blowed up again upon checking zboard 2 mosfets 30j124 were shorted again...y board is still ok ..please guide me in this case...
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: 42PJ350 clicking noise
Hello i have same problem with 42pj350 supply just clicking. i replaced 3br1565 diode 304 but i got same result there is no vs va some time i switching it give vs va but after on off it agian clicking. Which caps u chaged will u tell me@ del3165 ?Last edited by dhavalrpatil; 06-01-2017, 05:11 AM.
Leave a comment:
-
Re: Samsung 46ES6200 random dead problem
on main cap 340v steady
Leave a comment:
-
Re: Samsung 46ES6200 random dead problem
yes 5v stby is steady...ther is no 24volt line in this supply...on CNM803 in standy 12 is coming...but when load is connected 12 volt becomes 5v..., i think
there is no current in 12volt line......
Leave a comment:
-
Samsung 46ES6200 random dead problem
samsung 46ES6200 having random dead problems...checked power supply 12v becomes 5v -6v on load (sometimes), PSU number-BN44-00518B..any solution?...Last edited by dhavalrpatil; 04-28-2017, 04:08 AM.
No activity results to display
Show More
Leave a comment: