Hi,
Thanks but noticed a problem after looking back at some pics on the overclockers thread...These two points were bridged ....i removed solder with a braid but just presumed it was ment to join as it looked continuous...will this cause a problem, ive indicated the bridge with a red circle.
Hi, thanks for reply... i changed the d22 with STPS60170CT no insulator on leg, and it powers up , I think they must have changed psu at some point as monitor is A03 And psu is A02..none of the diodes/SCHOTTKY have insulators.
I've only had the monitor a few weeks bought off ebay
I dont mind doing again on a new psu, this one does not look that great..seems a bit warped compared to the 3007.. the insulators/ferrite beads seem to have ratings so not sure what to get.
Thanks
Hi on further inspection the power unit seems to be have been repaired before.
It still contains the original spec d22 but there is no insulator on it or on the 2 other diodes
that need to be desoldered ?
Do i need these ? are they ferrite beads..
Hi managed to fix dell 3007 wfp buy changing caps with a rubicon kit, now my dell 3008 has failed to power on. I will try this fix, but what is the more reliable monitor from experience? I don't need additional inputs or resolutions. 3008 seems to run a lot hotter...will probably sell one if i fix the 3008. Had my dell 24"
ultrasharp for years no issues
I have the 3008 open it has original d22...but looks like its been opened before.
the 3007 looks better internally and 3008 in looks
Managed to fix this, I changed the capacitors in the power supply. I bought a kit from ebay containing rubicon capacitors. It was'nt to difficult if you take your time. the hardest part was desoldering caps, but that got easier after a few attempts
I did'nt really expect it to work as symptoms were different to others and really thought it looked like a control board issue
Hi,
I have a problem with a dell 3007 wtp just wondered if its fixable...I've checked cable is dual link and tested pc with another 30" monitor all is ok...
The monitor runs the colour cycle test ok but images are disstorted when connected to pc.
Thanks for any help
Hi I have a dell 3007 wtp if you switch it on it runs through the color cycle test fine, but when i connect to pc image is disstorted, its not cables or pc as i have test with a 3008 wtp
is it fixable ?
Hi I have a dell 3007 wtp if you switch it on it runs through the color cycle test fine, but when i connect to pc image is disstorted, its not cables or pc as i have test with a 3008 wtp
is it fixable ?