Re: Dim Clock LCD on Jenn-Air wall oven



First - thanks to you and everyone who has contributed their success (and failure) stories.

I'm going to have a go at the cap replacements and basically need to know if the Panasonic FC, FM, and FR series are interchangeable in this application. Don't know much about component level specs, but the C3 68uF 35v have lifetimes of 1000, 2000, and 5000 hours for FC, FM, and FR respectively. FM and FR both have 130 mOhm impedence and 455 mA ripple current - FC has 350 mOhm impedence and 290 mA ripple current. All other...