Re: Hyvision by Megavision MV220 LCD monitor goes blank after 0.5-1 second
Replaced the KSC Cap in the inverter with Panasonic EEC-FC1E221BJ and the monitor is working now. Thanks for your help.
Announcement
Collapse
No announcement yet.
User Profile
Collapse
-
Re: Hyvision by Megavision MV220 LCD monitor goes blank after 0.5-1 second
Thanks for the quick reply. Measured winding on both transformers and am getting resistances of 905 and 915 ohm. I would think they are ok?
Connected another capacitor of the same value in parallel with the KSC (essentially making sure that I get the capcitance required) and it made no difference. Perhaps this cap needs to be replaced...
Checked the screen with a flashlight and I can see the computer icons (very dim) so definitely this is a 2 seconds to black issue type. It seems like the CCFL...
Leave a comment:
-
Hyvision by Megavision MV220 LCD monitor goes blank after 0.5-1 second
I need some help with my PC LCD Hyvision by Megavision MV220 monitor.
I am an electrical hobbyist that very much enjoys fixing things. I can solder/unsolder reasonably well and have a good understanding of electrical circuitry (although by trade am Mechanical Engineer).
History/problem statement:
Purchased monitor in 2007 and has been working flawlessly until 1 month ago. 1 month ago monitor would turn on for 1 sec show the computer screen and then go blank. I would reset the computer (thinking that it maybe the PC fault) and the monitor screen would come on. This...
-
Re: New Members - please post your introductions here
new member here...like so many others trying to learn and fix things myself. I derive great pleasure from doing so